[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [FW1] Can't set workstation object to internal




Joseph,

When you click on Network Objects->New->Workstation,
is Internal radial button greyed out?

Sounds like you're in read-only mode? Yes??

Robert

- -
Robert P. MacDonald, Network Engineer
e-Business Infrastructure
G o r d o n   F o o d    S e r v i c e
Voice: +1.616.261.7987 email: rmacdonald@gfs.com

>>> <Joseph_Vieira@dmr.com> 8/21/00 11:35:15 AM >>>
>
>Hello,
>
>I have FW1 4.1 SP2 on an NT machine.  When I go to create a new workstation
>object I can't set the location to internal.  The radio buttons are grayed 
>out
>and it set to external.  I can set other object (network, router, switch) to
>internal but not workstation.  Any ideas?
>
>Thanks,
>
>Joe




================================================================================
     To unsubscribe from this mailing list, please see the instructions at
               http://www.checkpoint.com/services/mailing.html
================================================================================